OD:Φ9.2×ID:Φ7.5×L:1045 |
OD:Φ9.8×ID:Φ8.0×L:1025 |
OD:Φ10.8×ID:Φ8.7×L:1020 |
OD:Φ9.2×ID:Φ7.3×L:1045 |
OD:Φ9.2×ID:Φ7.3×L:1080 |
OD:Φ10.2×ID:Φ8.6×L:1030 |
OD:Φ10.2×ID:Φ8.4×L:1020 |
OD:Φ10.2×ID:Φ8.6×L:1035 |
OD:Φ9.2×ID:Φ7.4×L:1032 |
OD:Φ9.0×ID:Φ7.4×L:1030 |
OD:Φ5.3×ID:Φ4.4×L:1096 |
OD:Φ6.5×ID:Φ5.5×L:1017 |
OD:Φ5.7×ID:Φ4.9×L:1090 |
OD:Φ5.8×ID:Φ4.8×L:1090 |
OD:Φ9.2×ID:Φ7.3×L:1035 |
OD:Φ9.0×ID:Φ7.3×L:1025 |
OD:Φ9.5×ID:Φ7.8×L:1050 |
OD:Φ9.4×ID:Φ7.7×L:1030 |
OD:Φ9.4×ID:Φ7.6×L:1030 |
OD:Φ12.75×ID:Φ10.75×L:1246 |
OD:Φ11.9×ID:Φ9.85×L:1246 |
OD:Φ11.4×ID:Φ9.5×L:1245 |
OD:Φ13×ID:Φ10.8×L:1285 |
OD:Φ13.2×ID:Φ10.9×L:1285 |
OD:Φ12.9×ID:Φ10.5×L:1640 |
OD:Φ12.85×ID:Φ10.7×L:1280 |
OD:Φ12×ID:Φ9.8×L:1285 |
OD:Φ12.2×ID:Φ9.8×L:1300 |
OD:Φ11.3×ID:Φ9.05×L:1291 |
OD:Φ12.2×ID:Φ9.8×L:1680 |
OD:Φ12.0×ID:Φ9.8×L:1290 |
OD:Φ10.7×ID:Φ8.63×L:1300 |
OD:Φ10.7×ID:Φ9.0×L:1303 |
OD:Φ10.6×ID:Φ8.6×L:1350 |
OD:Φ12.95×ID:Φ10.5×L:1300 |
OD:Φ12.1×ID:Φ9.84×L:1280 |
OD:Φ11.3×ID:Φ9.2×L:1350 |
OD:Φ12.95×ID:Φ10.5×L:1280 |
OD:Φ12.95×ID:Φ10.5×L:1290 |
OD:Φ11.5×ID:Φ9.5×L:1230 |
OD:Φ10.8×ID:Φ8.6×L:1210 |
OD:Φ12.0×ID:Φ9.8×L:1230 |
OD:Φ5.2×ID:Φ4.3×L:362 |
OD:Φ3.5×ID:Φ2.7×L:305 |
OD:Φ5.3×ID:Φ4.4×L:360 |
OD:Φ5.5×ID:Φ4.45×L:355 |
OD:Φ6.3×ID:Φ5.3×L:370 |
OD:Φ5.5×ID:Φ4.5×L:366 |
OD:Φ5.2×ID:Φ4.3×L:382 |
OD:Φ5.3×ID:Φ4.3×L:586 |
OD:Φ5.2×ID:Φ4.3×L:592 |
OD:Φ5.15×ID:Φ4.25×L:533 |
OD:Φ6.2×ID:Φ5.15×L:576 |
OD:Φ6.2×ID:Φ5.15×L:545 |
OD:Φ6.3×ID:Φ5.2×L:535 |
OD:Φ5.2×ID:Φ4.3×L:607 |
OD:Φ4.15×ID:Φ3.2×L:600 |
OD:Φ3.25×ID:Φ2.6×L:610 |
OD:Φ3.3×ID:Φ2.6×L:680 |
OD:Φ9.6×ID:Φ7.75×L:1060 |
OD:Φ10×ID:Φ8.1×L:1068 |
OD:Φ9.4×ID:Φ7.7×L:1059 |
OD:Φ6.2×ID:Φ5.0×L:1104 |
OD:Φ9.3×ID:Φ7.4×L:1075 |
OD:Φ10.8×ID:Φ8.6×L:1007 |
OD:Φ8.2×ID:Φ6.6×L:1087 |
OD:Φ9.6×ID:Φ7.6×L:1090 |
OD:Φ9.5×ID:Φ7.6×L:1090 |
OD:Φ9.7×ID:Φ7.9×L:1052 |
OD:Φ11.8×ID:Φ10.0×L:1057 |
OD:Φ6.2×ID:Φ4.9×L:1090 |
OD:Φ9.5×ID:Φ7.6×L:1008 |
OD:Φ9.8×ID:Φ7.8×L:1070 |
OD:Φ12.0×ID:Φ9.8×L:1054 |
OD:Φ12.9×ID:Φ10.5×L:1255 |
OD:Φ13×ID:Φ10.5×L:1255 |
OD:Φ12.9×ID:Φ10.6×L:1242 |
OD:Φ12.95×ID:Φ10.5×L:1448 |
OD:Φ12.9×ID:Φ10.7×L:1251 |
OD:Φ11.35×ID:Φ9.6×L:1254 |
OD:Φ12.9×ID:Φ10.5×L:1295 |
OD:Φ12.9×ID:Φ10.5×L:1450 |
OD:Φ12.9×ID:Φ10.5×L:1450 |
OD:Φ5.35×ID:Φ4.4×L:561 |
OD:Φ6.15×ID:Φ5.06×L:560 |
OD:Φ5.4×ID:Φ4.45×L:404 |
OD:Φ10×ID:Φ8.1×L:1081 |
OD:Φ10.2×ID:Φ8.1×L:1045 |
OD:Φ10.2×ID:Φ8.1×L:1059 |
OD:Φ13×ID:Φ10.55×L:1465 |
OD:Φ12.9×ID:Φ10.75×L:1500 |
OD:Φ11.7×ID:Φ9.5×L:1453 |
OD:Φ13.4×ID:Φ10.7×L:1465 |
OD:Φ13×ID:Φ10.5×L:1440 |
OD:Φ12.8×ID:Φ10.6×L:1371 |
OD:Φ10.7×ID:Φ8.9×L:1255 |
OD:Φ11.2×ID:Φ8.7×L:1256 |
OD:Φ4.1×ID:Φ3.18×L:315 |
OD:Φ5.05×ID:Φ4.05×L:300 |
OD:Φ5.2×ID:Φ4.3×L:355 |
OD:Φ5.2×ID:Φ4.4×L:355 |
OD:Φ5.3×ID:Φ4.38×L:585 |
OD:Φ5.15×ID:Φ4.3×L:600 |
OD:Φ5.4×ID:Φ4.4×L:600 |
OD:Φ4.25×ID:Φ3.5×L:618 |
OD:Φ3.7×ID:Φ2.8×L:625 |
OD:Φ3.3×ID:Φ2.7×L:610 |
OD:Φ3.18×ID:Φ2.5×L:621 |
OD:Φ4.1×ID:Φ3.1×L:600 |
OD:Φ5.2×ID:Φ4.3×L:360 |
OD:Φ5.4×ID:Φ4.3×L:362 |
OD:Φ4.15×ID:Φ3.2×L:365 |
OD:Φ3.7×ID:Φ2.8×L:625 |
إن أنبوب إدخال المنظار هو ميزة تمييز رئيسية بين المنظار المصممة لعلاج أمراض الجهاز الهضمي.على الرغم من وجود اختلافات واضحة تبعا لتطبيق المنظارعلى سبيل المثال، طول المُنظَر الغذائي الطويل جداً، ورقاعة المُنظَر الغذائي عبر الأنف) ، الاختلافات الدقيقة بين نماذج المُنظَر الغذائي هي مهمة بنفس القدر.هذا ينطبق بشكل خاص على أجهزة الرؤية القولونية؛ على الرغم من أن أطباء التنظير النهائي قد يفضلون استخدام نموذج خاص من التنظير القولوني لأسباب مختلفة،خصائص الأداة في أنبوب إدخال أكثر من أي شيء آخر من المرجح أن يؤدي إلى اختيار طبيب الأندوسكوب أداة كولونوسكوب معينة كأداة اختيارإذا كانت هناك مواصفات واحدة للأداة يمكن أن تحدد السرعة والسهولة التي يمكن أن يضع بها أخصائي المراجع الداخلية الأداة ، فهي الخصائص الميكانيكية لأنبوب الإدراج.
يحتوي أنبوب الإدراج عادةً على (1) أنابيب لامتصاص (النيابة عن الحيوانات) وتغذية الهواء والماء ؛ (2) غالبًا أنبوب إضافي لطائرة المياه الأمامية ؛ (3) أربعة أسلاك لتحكم الزاوية ؛(4) الأسلاك الكهربائية الدقيقة التي تربط مستشعر الصورة (CCD) في الطرف البعيد من منظار الغشاء مع معالج الفيديوو (5) ألياف زجاجية حساسة لإيصال الضوء من مصدر الضوء إلى الطرف البعيد من منظار الغشاء.يحتوي أجهزة الكولونوسكوب ذات مرونة أنبوب الإدراج القابلة للتعديل على مكون إضافي - سلك تشديد للسيطرة على صلابة أنبوب الإدراجيحتوي أجهزة المثني عشر أيضاً على غطاء سلكي / ملفوف إضافي يمتد على طول أنبوب الإدراج للسيطرة على وضعية رفع القرص إلى الأعلى والأسفل.